21.
Glycaemia, a classical indicator of stress, xanthine oxidase and aldehyde oxidase which are involved in phase I detoxication were investigated in two different fish species from two rivers with different pollution levels in the Western Niger-Delta. Four sampling zones covering the entire lengths of Warri and Ethiope Rivers respectively were used in this study. For each species of fish five were obtained from a sampling zone in a river. Blood glucose was significantly higher (P < 0.001) in M. electricus from Warri River (82.13 +/- 5.50 mg cm(-3)) compared to the same species from Ethiope River (36.47 +/- 1.49 mg cm(-3)). With the same parameter a similar profile was observed for C. gariepinus; Warri River (56.92 +/- 10.31 mg cm(-3)); Ethiope River (37.65 +/- 0.90 mg cm(-3)) which was also significant (P < 0.01). The activity of xanthine oxidase in M. electricus from Warri River (255.80 +/- 41 it mol cm(-3)) was significantly higher (P < 0.001) compared to the value obtained for the same species (108 +/- 22.36 micro mol cm(-3)) from Ethiope River. Also the activity of xanthine oxidase in C. gariepinus from Warri River (197 +/- 34.65 micro mol cm(-3)) was significantly higher (P < 0.001) when matched with the value obtained for the same species (78.40 +/- 26.84 micro mol cm(-3)) from Ethiope River. That blood glucose level was related to xanthine oxidase activity in the two fish species from Warri River was supported by the high positive correlation between these two parameters (M. electricus. r = 1: C. gariepinus, r = 0.71). The activity of aldehyde oxidase in C. gariepinus from Warri River (143.80 +/- 28.45 micro mol cm(-3)) was significantly higher (P < 0.001) compared to the value obtained for the same species (61.20 +/- 15.21 micro mol cm(-3)) from Ethiope River. A similar profile in aldehyde oxidase activity observed for M. electricus; Warri River (130 +/- 28.39 micro mol cm(-3)); Ethiope River (89 +/- 19.70 micro mol cm(-3)) but an inferior statistical variation (P < 0.05) was obtained. The results obtained in this study indicate that the level of xanthine oxidase in M. electricus is a more specific marker and to a lesser extent its activity in C. gariepinus in monitoring environmental stress due to pollution. 相似文献
22.
23.
Phthalate and PAH concentrations in dust collected from Danish homes and daycare centers 总被引:1,自引:0,他引:1
Sarka Langer Charles J. Weschler Andreas Fischer Gabriel Bekö Jørn Toftum Geo Clausen 《Atmospheric environment (Oxford, England : 1994)》2010,44(19):2294-2301
As part of the Danish Indoor Environment and Children’s Health (IECH) study, dust samples were collected from 500 bedrooms and 151 daycare centers of children (ages 3 to 5) living on the island of Fyn. The present paper reports results from the analyses of these samples for five phthalate esters (diethyl phthalate (DEP), di(n-butyl) phthalate (DnBP), di(isobutyl) phthalate (DiBP), butyl benzyl phthalate (BBzP), di(2-ethylhexyl) phthalate (DEHP)) and three PAHs (pyrene, benz[a]anthracene (B[a]A) and benzo[a]pyrene (B[a]P)). The three PAHs and DEHP were detected in dust samples from all sites, while DEP, DnBP, DiBP and BBzP were detected in more than 75% of the bedrooms and more than 90% of the daycare centers. The dust mass-fractions of both phthalates and PAHs were log-normally distributed. With the exception of DEP, the mass-fractions of phthalates in dust were higher in daycare centers than homes; PAH mass-fractions in dust were similar in the two locations. There was no correlation among the different phthalates in either homes or daycare centers. In contrast, the PAH were correlated with one another – more strongly so in homes (R2 = 0.80–0.90) than in daycare centers (R2 = 0.28–0.45). The dust levels of several phthalates (BBzP, DnBP and DEHP) were substantially lower than those measured in a comparable study conducted 6–7 years earlier in Sweden. Although usage patterns in Denmark differ from those in Sweden, the current results may also reflect a change in the plasticizers that are used in common products including toys. PAH levels were roughly an order of magnitude lower than those measured in Berlin and Cape Cod residences, suggesting that the Danish sites are less impacted by motor vehicle emissions. 相似文献
24.
The structure of turbulence near a tall forest edge: the backward-facing step flow analogy revisited 总被引:5,自引:0,他引:5
Matteo Detto Gabriel G Katul Mario Siqueira Jehn-Yih Juang Paul Stoy 《Ecological applications》2008,18(6):1420-1435
Flow disturbances near tall forest edges are receiving significant attention in diverse disciplines including ecology, forest management, meteorology, and fluid mechanics. Current theories suggest that near a forest edge, when the flow originates from a forest into a large clearing, the flow retains its forest canopy turbulence structure at the exit point. Here, we propose that this framework is not sufficiently general for dense forested edges and suggest that the flow shares several attributes with backward-facing step (BFS) flow. Similar analogies, such as rotor-like circulations, have been proposed by a number of investigators, though the consequences of such circulations on the primary terms in the mean momentum balance at the forest clearing edge have rarely been studied in the field. Using an array of three triaxial sonic anemometers positioned to measure horizontal and vertical gradients of the velocity statistics near a forest edge, we show that the flow structure is more consistent with an intermittent recirculation pattern, rather than a continuous rotor, whose genesis resembles the BFS flow. We also show that the lateral velocity variance, v'2, is the moment that adjusts most slowly with downwind distance as the flow exits from the forest into the clearing. Surprisingly, the longitudinal and vertical velocity variances (u'2 and w'2) at the forest edge were comparable in magnitude to their respective values at the center of a large grass-covered forest clearing, suggesting rapid adjustment at the edge. Discussions on how the forest edge modifies the spectra and co-spectra of momentum fluxes, effective mixing length, and static pressure are also presented. 相似文献
25.
Heavy metal contamination from mining sites in South Morocco: Monitoring metal content and toxicity of soil runoff and groundwater 总被引:5,自引:0,他引:5
El Khalil H El Hamiani O Bitton G Ouazzani N Boularbah A 《Environmental monitoring and assessment》2008,136(1-3):147-160
The aim of the present work is the assessment of metal toxicity in runoff, in their contaminated soils and in the groundwater
sampled from two mining areas in the region of Marrakech using a microbial bioassay MetPLATE™. This bioassay is based on the
specific inhibition of the β-galactosidase enzyme of a mutant strain of Escherichia coli, by the metallic pollutants. The stream waters from all sampling stations in the two mines were all very toxic and displayed
percent enzyme inhibition exceeding 87% except SWA4 and SWB1 stations in mine C. Their high concentrations of copper (Cu) and zinc (Zn) confirm the acute toxicity shown by MetPLATE.
The pH of stream waters from mine B and C varied between 2.1 and 6.2 and was probably responsible for metal mobilization,
suggesting a problem of acid mine drainage in these mining areas. The bioassay MetPLATE™ was also applied to mine tailings
and to soils contaminated by the acidic waters. The results show that the high toxicity of these soils and tailings was mainly
due to the relatively concentration of soluble Zn and Cu. The use of MetPLATE™ in groundwater toxicity testing shows that,
most of the samples exhibited low metal toxicity (2.7–45.5% inhibition) except GW3 of the mine B (95.3% inhibition during
the wet season and 82.9% inhibition during the dry season). This high toxicity is attributed to the higher than usual concentrations
of Cu (189 μg Cu l−1) and Zn (1505 μg Zn l−1). These results show the potential risk of the contamination of different ecosystems situated to the vicinity of these two
metalliferous sites. The general trend observed was an increase in metal toxicity measured by the MetPLATE with increasing
total and mobile metal concentrations in the studied matrices. Therefore, the MetPLATE bioassay is a reliable and fast bioassay
to estimate the metals toxicity in the aquatic and solids samples. 相似文献
26.
27.
Roussel S Reboux G Bellanger AP Sornin S Grenouillet F Dalphin JC Piarroux R Millon L 《Journal of environmental monitoring : JEM》2008,10(6):724-729
Dwellings showing a presence of moulds are considered to be unhealthy both by the inhabitants and by sanitary authorities. Although the thresholds of pathogenicity have not yet been established, the toxic, allergic and infectious risk of indoor moulds is better understood today. A study on indoor fungi contamination for 128 dwellings was done between October and May in France. It concerned 69 dwellings, the occupants of which either complained to the sanitary authorities about problems of moulds and humidity or consulted a doctor who related their symptoms to housing conditions. Fifty-nine other dwellings, the occupants of which were healthy, constituted the control group. We present the statistical analysis of questionnaires, which aimed to clarify characteristics of dwellings associated with high concentrations of airborne moulds. Air samples were taken with an impactor in 500 rooms. On visiting dwellings, investigators obtained answers to 25 questions concerning characteristics of inhabitants and living space, as well as the presence of mould indicators. Indoor and outdoor temperature and indoor relative humidity of air measurements were taken. The total concentration of fungi in the air was significantly higher in ground floor apartments versus those on other floors (p = 0.047), in small and highly occupied dwellings (p = 0.03 and 0.003), in dwellings with electric heating (p = 0.04), without a ventilation system (p = 0.003), with water damage (p = 0.003), and finally, in those where the investigator noted an odour of moisture or visible moulds (p < 0.001). The efficacy of the latter criteria in the evaluation of insalubrity is discussed. 相似文献
28.
Simona Caprarescu Mihai Cosmin Corobe Violeta Purcar Catalin Ilie Spataru Raluca Ianchis Gabriel Vasilievici Zina Vuluga 《环境科学学报(英文版)》2015,35(9):27-37
Heterogeneous membranes were obtained by using styrene-acrylonitrile copolymer (SAN) blends with low content of ion-exchanger particles (5 wt.%). The membranes obtained by phase inversion were used for the removal of copper ions from synthetic wastewater solutions by electrodialytic separation. The electrodialysis was conducted in a three cell unit, without electrolyte recirculation. The process, under potentiostatic or galvanostatic control, was followed by pH and conductivity measurements in the solution. The electrodialytic performance, evaluated in terms of extraction removal degree (rd) of copper ions, was better under potentiostatic control then by the galvanostatic one and the highest (over 70%) was attained at 8 V. The membrane efficiency at small ion-exchanger load was explained by the migration of resin particles toward the pores surface during the phase inversion. The prepared membranes were characterized by various techniques i.e. optical microscopy, Fourier transform infrared spectroscopy, scanning electron microscopy, thermogravimetric analysis and differential thermal analysis and contact angle measurements. 相似文献
29.
Estela Santalla Verónica Córdoba Gabriel Blanco 《Journal of the Air & Waste Management Association (1995)》2013,63(8):909-917
The objective of this work was the application of 2006 Intergovernmental Panel on Climate Change (IPCC) Guidelines for the estimation of methane and nitrous oxide emissions from the waste sector in Argentina as a preliminary exercise for greenhouse gas (GHG) inventory development and to compare with previous inventories based on 1996 IPCC Guidelines. Emissions projections to 2030 were evaluated under two scenarios—business as usual (BAU), and mitigation—and the calculations were done by using the ad hoc developed IPCC software. According to local activity data, in the business-as-usual scenario, methane emissions from solid waste disposal will increase by 73% by 2030 with respect to the emissions of year 2000. In the mitigation scenario, based on the recorded trend of methane captured in landfills, a decrease of 50% from the BAU scenario should be achieved by 2030. In the BAU scenario, GHG emissions from domestic wastewater will increase 63% from 2000 to 2030. Methane emissions from industrial wastewater, calculated from activity data of dairy, swine, slaughterhouse, citric, sugar, and wine sectors, will increase by 58% from 2000 to 2030 while methane emissions from domestic will increase 74% in the same period. Results show that GHG emissions calculated from 2006 IPCC Guidelines resulted in lower levels than those reported in previous national inventories for solid waste disposal and domestic wastewater categories, while levels were 18% higher for industrial wastewater.
Implications: The implementation of the 2006 IPCC Guidelines for National Greenhouse Inventories is now considering by the UNFCCC for non-Annex I countries in order to enhance the compilation of inventories based on comparable good practice methods. This work constitutes the first GHG emissions estimation from the waste sector of Argentina applying the 2006 IPCC Guidelines and the ad doc developed software. It will contribute to identifying the main differences between the models applied in the estimation of methane emissions on the key categories of waste emission sources and to comparing results with previous inventories based on 1996 IPCC Guidelines. 相似文献
30.
Liu S Tao S Liu W Dou H Liu Y Zhao J Little MG Tian Z Wang J Wang L Gao Y 《Environmental pollution (Barking, Essex : 1987)》2008,156(3):651-656
Passive air sampling (PAS) was employed to study the occurrence of gaseous and particle-bound PAHs in the North Chinese Plain. The averaged concentrations of gaseous and particle-bound PAHs were 485 ± 209 ng/m3 and 267 ± 161 ng/m3, respectively. The PAHs concentrations at urban sites were generally higher than those at rural ones with ratios <1.5 in spring, summer and fall, but differences between them were not significant for the wintertime and annually averaged concentrations. This urban-rural distribution pattern was related to the PAHs emission sources. PAHs spatial variation can be partially (49%) explained by emission with a simple linear regression method. Both the gaseous and particle-bound PAHs were highest in winter and lowest in summer, with winter/summer ratios of 1.8 and 8, respectively. Emission strength was the most important factor for the seasonality. 相似文献